Fixed

  • On openccu-lite every write of a decimal value failed - a dimmer's or a
    blind's LEVEL, a thermostat's set point, an ON_TIME, through value,
    set value, rpc and the other nodes alike. A FLOAT datapoint is sent as
    a typed double, which over XML-RPC is homematic-xmlrpc's
    {explicitDouble: n}; the lite-rpc connection of 4.7.0 passed that object
    on as it was, so the interface process got a struct where a number belongs
    and refused it (Failure from rfd and hs485d,
    -5 Invalid parameter or value from hmipserver). The lite-rpc connection
    now sends lite-rpc's own typed double, {double: n} (or the plain number
    on a system that does not announce it) - in setValue, in a paramset of
    putParamset and in a multicall. The direct connection to a CCU is unchanged. Until this version
    the workaround was CCU in the connection node's openccu-lite interfaces.
  • Errors of the lite-rpc connection said less than they should: a fault
    of the interface process was logged as fault -1 undefined and reached the
    flow as OccuLiteError: Failure, and a token without the needed rights did
    not say which right it lacks. The fault now carries its code and text, and a
    refused call names the missing scope.

Commits since v4.7.0

  • 4.7.1 - decimal values through lite-rpc (912d570)
  • docs(changelog): 4.7.1 (d2dfa6b)
  • fix(lite): FLOAT values go to lite-rpc as {double}, and the client's errors are translated (8f35489)
  • ci(release): ask the Node-RED flow library to pick up a new version (519f40b)