github stuerp/foo_vis_spectrum_analyzer v0.14.0.0

one hour ago
  • New: Composite three-tier FFT
    • It uses all the settings of the normal FFT but it splits the spectrum into three logarithmic ranges.
    • The bass tier uses four times the number of bins; the middle tier uses two times the number of bin.
  • New: Decades frequency distribution. It generates frequency bands whose center frequency is a multiple of 10, 100 or 1000 Hz.
  • New: Hop size support for the spectrum analyzers.
    • The Hop size fraction parameter specifies a hop size relative to the FFT size. Smaller hops (larger fraction) produce more frequent analysis updates.
    • The default value is 0% which results in the old behavior.
  • New: Reassignment sharpening. Github Issue 63.
    • Produces a sharper spectrum by relocating energy to a bin that represents more accurately the frequency at the cost of extra processing.
    • Works for an FFT and Composite FFT using Standard coefficient mapping.
    • Disabled by default.
  • New: Peak detector. It identifies the strongest local maxima in the current frequency spectrum.
    • Enable it using the configuration dialog on the Transform page.
    • Two new styles (Peak Marker and Peak Text) allow you to customize the rendering.
  • New: Alternate full screen mode for DUI. It reuses the current window (and preset) instead of starting a second instance.
    • Enable it using the configuration dialog on the Common page.
    • Double click the left mouse button to enter fullscreen mode. Doubleclick again or press Escape to exit.
    • You can use the Page Up and Page Down key to move the window between monitors.
  • New: Don't render anything to reduce CPU usage when component window is completely covered.
  • New: Balance / Correlation Meter uses the Fall Speed setting instead of a fixed decay speed.
  • New: Eye Candy visualizer with multiple effects in 5 categories.
  • Improved: The alignment of the X-axis frequency labels with the band centers.
  • Improved: Decades frequency setting generates at least the requested number of frequency bands.
  • Improved: The composite three-tier FFT analyzer cross-fades between the tiers using ratios derived from the FFT's bin width instead of fixed ratios.
  • Improved: Goniometer Mono and Triband modes react better to the color changes of the Signal style.
  • Improved: Oscilloscope and Goniometer now supports local styles and Overlap mode.
  • Improved: Streamlined the high-DPI calculations.
  • Changed: Refactored the whole audio processor hierarchy to facilitate maintenance, improve performance and make future expansion easier.
  • Changed: Various little tweaks and corrections to the peak marker animation.
  • Fixed: Styles that use the artwork colors were not correctly initialized at startup. (Regression)
  • Fixed: Peak Meter render bug when multiple graphs are used in the layout. It was caused by unfinished code for this use case.
  • Fixed: Spectrogram showed spectrum residue to the left and top when scrolling in high-DPI scenarios.
  • Fixed: Cosmetic error. The label of the top tick of a Y-axis of the spectrogram was cut off when the tick aligned with the top of the viewport.
  • Fixed: Peak Meter static content did not react to changed color selections.
  • Fixed: Spectrogram showed spectrum residue to the left and top when scrolling in high-DPI scenarios. (Confirmed fix).
  • Fixed: The input ring buffer did not handle non-radix 2 FFT's correctly.
  • Fixed: Static content did not always respond to color changes.
  • Fixed: Oscilloscope and Goniometer did not position themselves correctly in a multiple graph scenario.

Don't miss a new foo_vis_spectrum_analyzer release

NewReleases is sending notifications on new releases.