Automated release from CI pipeline
Changes:
research(R17): industrial safety — second vertical composing loop primitives (#736)
Second exotic vertical demonstrating loop primitives compose to industrial
safety. Parallel to R16 healthcare with different ADR-113 matrix rows
(presence + vital-signs at coarser resolution) and R7 mincut becomes
BINDING (not nice-to-have) due to hostile industrial RF environment.
Three deployment scenarios:
- Warehouse zone (5y): 0/zone vs 00-2000 camera+monitoring
- Construction site (10y): per-project federation
- Refinery/chemical plant (15y): adds CSI to gas+cam+badge infrastructure
R17 vs R16 parallel:
- R16: stationary patients, 30 m^2 ward, vital-signs row (chest, N=5), HIPAA
- R17: mobile workers, 100-1000 m^2 zone, presence row (body, N=3-4), OSHA
SAME ARCHITECTURE, different parameter regime.
Five specialised cog roadmap items:
- cog-fall-detection (5y): R12.1 + PPE-tuning
- cog-zone-occupancy (5y): R12 PABS + R6.2.5
- cog-lone-worker-vitals (5y): R14 V1 rate-only
- cog-worker-fatigue (10y): R10 gait + R15
- cog-multi-zone-orchestrator (5y): R6.2.5 + ADR-105 fed
Why R7 mincut becomes binding: industrial RF has legitimate noise
(cell, BLE tools, walkie-talkies) that must be disambiguated from
sensor compromise. N >= 4 anchors required (already met by ADR-113
for multi-feature cogs).
PPE-specific body model needed (R6.1 follow-up):
Hard hat / high-vis / harness / tool belt / steel-toed boots change
per-part reflectivity by ~5-15%. ~1-2 weeks labelled-data work for
cog-industrial-pose.
R10 gait taxonomy extends within humans:
- Walking: 1.2-2.5 Hz
- Fatigued: 0.8-1.5 Hz (slower + asymmetric)
- Impaired: asymmetry > 25%
OSHA-aligned pre-incident fatigue detection.
Honest scope:
- Synthetic data only; bench validation required for OSHA-grade
- PPE-specific body model unbuilt
- Outdoor/weather effects partly transfer from R10
- Worker consent + audit trail integration per-customer
R17 closes parallel-vertical demonstration: loop has now shown
VERTICAL-AGNOSTIC INFRASTRUCTURE:
- R10 wildlife
- R11 maritime
- R14 empathic appliances (home)
- R16 healthcare
- R17 industrial safety
Five exotic verticals + cross-thread identity work. Outputs that
generalise beyond original problems = mark of well-factored research.
Composes:
- R1, R5, R6/R6.1, R6.2.5, R7 (binding here), R10, R12/R12.1, R13 NEG,
R14, R15 — all loop threads - ADR-113 placement + ADR-105-109 privacy/PQC chain
- R16 parallel pattern
Coordination: ticks/tick-33.md, no PROGRESS.md edit.
Docker Image:
ghcr.io/ruvnet/RuView:8213741879cef941b389cd4710f272b6b62e93ef