Backup heater: its second step alone counts as the heater on (#726, @Exaduis). On an EHBX04EF6V the unit switches BUH Step2 on with BUH Step1 off. The day's backup heater time only counted step 1, and the drawing on the home page and its Backup heater mark only looked at step 1: the heater ran unseen. Either step now counts. The electricity and the heat already counted step 2, with the power entered for it in Settings → Statistics. BUH Step2 is not in the default selection: tick it in Values if your heater has two steps.
Hot water target down to 25 °C on software 20017704, in the working memory only (#727, by @Toesoe). With Keep the targets in the unit's working memory only ticked, the hot water target of the 4-8 kW EBLA/EDLA E monoblocs and ECH2O EF/EG boards on 20017704 goes down to 25 °C instead of 45 °C, as on 20002203. Tried on an EBLA08E23V3: 25 °C and 41 °C were taken and aimed for. The memory cannot hold such a target; unticking the box with one held puts the unit's curve back.
Diagnostics: the memory dump asks for both ranges (#725, @misko903). The hint proposed 0x3000-0x5FFF as the place of the settings and counters. True for the softwares from 2019 on; those of 2018 and before keep all of it below 0x3000. The page now asks for two dumps, 0x0800-0x2FFF and 0x3000-0x5FFF, and the README asks for them along with the software version when the card says "not available".
Update: System → Firmware update → Check for an update, or the web installer. Card: 1.0.37, unchanged.