Home page: "Indoor" instead of "Living room" (#599, @OllieD). The house on the home page showed the unit's room temperature under "Living room". That sensor is where the thermostat hangs, a hallway as often as a living room, and the heating is the whole house's: the label is now "Indoor". The Home Assistant card 1.0.37 shows the name of the entity instead: rename the entity in Home Assistant and the card follows.
Settings: where to read the outdoor unit's supply (#721, @misko903). Under Outdoor unit supply the page now says where the answer is: on the outdoor unit's nameplate, 1~ 230 V is 1 phase and 3N~ 400 V is 3 phases; the 6V or 9W in the indoor unit's name is the supply of its backup heater, not of the compressor. With 3 phases set for a single-phase outdoor unit, the estimated electricity is three times too high.
Targets kept in the working memory only: the card no longer says "saved in a moment". With Keep the targets in the unit's working memory only ticked, the memory is never written, and the target card kept saying "Applied, saved in the unit in a moment." for as long as a target was held. It now says "Held in the working memory of the unit, not saved." Nothing changes in what is written to the unit.
Docs (#718, @bunni1310): the allowed range of a target is the unit's own, read again every 10 minutes. After a change of [9-00] or [9-01] on the interface the card and the number entity follow by themselves, as seen on an Altherma Hybrid (software 9051), where the restore of the unit's curve over MQTT was run as well.
No change in what the board reads or sends.
Update: System → Firmware update → Check for an update, or the web installer. Card: 1.0.37.