Zeros published as readings while the unit restarts (#714, @sh41). When the unit restarts (its user interface does it after a change of field settings), its board goes on answering for about two minutes with zeros in place of most values, and ESPAltherma published them: outdoor temperature 0, operation mode Fan Only, thermostat off, in Home Assistant's history and in the board's own statistics. No value tells by itself, but registry 0x00, the outdoor unit's identification, does: it loses its content at the first bad reply and is the last to get it back (three restarts recorded every 5 s by @sh41 on an EHBX16CB3V). It is now read before and after the others at every poll, and a poll taken while it is incomplete is kept back: nothing is published, the readings stay what they were, and the event history says Heat pump restarting then Heat pump back after … s. After five minutes the readings follow what the unit answers again, whatever it is. Not covered: the units read with protocol S (no such registry), and a board that starts together with the unit, as after a power cut (it has not seen the registry complete yet). /api/status has hp.restarting while it lasts. One change for everybody: the values of a poll now change together at its end, instead of registry by registry.
Altherma Hybrid on hydro board software 9051: targets, power limit, unit counters (#716, @bunni1310). The EHYHBH on that software answered "not available". Mapped from the owner's two memory dumps: both curves, their ranges and the leaving water target read as the interface showed them, the unit's name is where the memory starts, and the heat meter equals the sum of the heat of its three modes. Nothing written on a unit yet: check that the card shows your curve and range before asking a target, and compare Unit meter with the interface's energy and operating hours screens. The active limit and the tank's ceiling are not placed on this software: not shown.
Cooling target on hydro board software 20017704 (#719 by @Toesoe). The experimental cooling target, until now on 20002203 only, also works on 20017704, the software of the 4-8 kW EBLA/EDLA E monoblocs and ECH2O E boards. Its addresses were read on an EBLA08E23V3, where the unit followed a target set from ESPAltherma within seconds in cooling mode.
Update: System → Firmware update → Check for an update, or the web installer. Card: 1.0.36, unchanged.