github raomin/ESPAltherma v2.0.0-beta.33

pre-releaseone hour ago

Home Assistant 2026.11: every entity "no longer provided by the mqtt integration" (#703, @TungstenE2). Since beta.30 the board gives Home Assistant a link to its own page, http://<name>.local/, built from Name on the network (Settings → This device). That name is free text. With a space in it the link is not an address; Home Assistant 2026.11 refuses it, and with it the whole message that announces the values: after its next restart none of the heat pump's entities are set up. Earlier versions of Home Assistant accepted it. The link is now sent only for a name made of letters, digits, hyphens and underscores, the ones <name>.local opens with. With any other name the device has no Visit link and everything else is as before. Nothing to do in Home Assistant: the entities come back at the board's first connection after the update. If you stay on beta.30 to beta.32, a name without spaces does the same.

Cooling target and additional zone target (hydro board software 20002203, experimental) (#701, @ppuetsch). Two more boxes under Settings → Experimental, each with its card on the home page and its number and restore button in Home Assistant, as the leaving water target has:

  • Cooling target: the leaving water target of the main zone while the unit cools, written into its cooling curve ([1-08] / [1-09]), within the unit's cooling range. It needs the main zone's setpoint mode weather dependent.
  • Additional zone target: the leaving water target of the additional zone while the unit heats, written into its curve ([0-00] / [0-01]). The unit never aims the additional zone lower than the main zone.

Both were written and read back on an EHBX08EF6V. Not seen yet: a cooling run on a target set from here, and two zones with real valves. Other softwares do not offer them. Details in doc/control.md.

Smaller.

  • The installer site and the demo count their page views (Cloudflare Web Analytics, which sets no cookie). The demo, which answers in place of a board, took the counter's request for one of the board's: it now only answers the firmware upload in place of the browser.
  • Docs, 20002203: [0-00] and [0-01] were the wrong way round, [0-00] is the high outdoor temperature end of the additional zone's curve.

Update: System → Firmware update → Check for an update, or the web installer. Card: 1.0.36, unchanged.

Don't miss a new ESPAltherma release

NewReleases is sending notifications on new releases.