0.1.0a58
Battery capacity
- Some third-party packs (a Pylontech Force H1, for one) report no capacity, so the capacity and the three battery charge sensors showed a 0.0 kWh battery. A reported 0 is now shown as unknown.
- Configure, Battery: the capacity your inverter reports is shown beside a new override box. Fill it in where the inverter reports none, or to use your battery's usable capacity from its datasheet. It feeds the three battery charge sensors only; it never changes how a Sungrow pack is recognised or how much power you can set.
The dashboard
- The Sungrow dashboard is offered as soon as the integration's frontend file loads, before any of the cards it uses. A card that fails to load now costs only that card, not the whole dashboard.
The diagnosis and the capability test
- Diagnosis, next attempt: where a check that has become possible can bring the next automatic run forward, the sensor and the step name that earlier start. A run not yet judged shows no time.
- The capability test asks the inverter for a forced discharge only when the battery is above 15 % (and 5 points above its minimum). Below that, a pack can sit at 0 W because of its own floor, and the test read that as a failed write.
- Discharge windows are confirmed on firmware P023 (an SH6.0RT-V112, thanks to a contributor's capability test), in addition to P020 and P022.
The flow cards are Power Flow Card Plus and Energy Flow Card Plus by flixlix (MIT).