0.1.0a49 — auto repeat tests the forced startup, and a restart sends one start
- Auto repeat now runs the forced startup check by itself. When it finds
the inverter asleep in standby with the battery at its minimum and no PV,
usually at night, it wakes it through register 13017, watches it start,
switches it off again and watches it go back to standby. Until now that
check only ran from therun_capability_testaction. The register is left
off afterwards. - The Forced startup under low SoC switch on SAPPHIRE-H P022, watched
on an SH8.0RT, beside P020 and P023. - A restart sends the start command once. At night the inverter waits a
few minutes in Standby before it starts; the test took that for a lost
command and sent it again every minute. It now waits. - Inverter self consumption is averaged over 15 minutes, and a new
Inverter self consumption energy (estimated) sensor adds it up. - A new readings check, daily counters keep up with the totals, names a
daily counter that stands still while its lifetime counter rises, such as a
daily import stuck at 0 through a night (#797). - The terminal diagnosis: a dry run of the forced startup no longer waits ten
minutes, and a restart alone runs at night.
Install: Settings → Marketplace, or update the preview repository.