0.1.0a41 (preview)
Setup
- An inverter whose network port takes its address by DHCP is now offered for setup: Sungrow's hardware prefix is enough for a card under Settings → Devices & services → Discovered. Nothing is read from it until you confirm, and a device already found over mDNS is still offered only once.
- A RAK WiFi module plugged into an inverter can be linked to it: the inverter's page then shows the module with a link to its web page, and deleting that device unlinks it again.
Diagnosis and tests
- While an extended test writes, the controls it is testing refuse a write of yours and say so, instead of the two crossing. They stay available, so an automation sees the error, and "Diagnosis: controls held by test" shows the hold.
- A control you set yourself is kept: where a run left a snapshot behind, your value is the one that stays.
- Auto repeat waits 10 minutes after a control you wrote, and an hour after an EV charger write, before it starts a wallbox run.