0.1.0a36: through a WiNet-S, the capability test no longer reports settings as not supported on a stale readback

A WiNet-S answers a register with the value it held before it forwarded a
write. When the capability test read back the old value through one, it
counted the setting as not supported, although the dongle's answer says
nothing about the inverter. At one installation this marked the battery's
maximum charge power, maximum discharge power and maximum state of charge as
not supported, while the same runs watched the inverter obey the maximum
state of charge.

  • Through a WiNet-S, such a readback now counts as inconclusive, and
    auto repeat does not wait for it. Over the inverter's own network port it
    still counts as not supported, which there it is.
  • Runs your Home Assistant already kept are read the same way: after the
    update, Diagnosis: tests not supported drops these settings by itself.
    Nothing needs to be cleared or run again.