github mkaiser/Sungrow-SHx-Inverter-Modbus-Home-Assistant v0.1.0a19

pre-release3 hours ago

Release 0.1.0a19

  • The survey now reads an iHomeManager into a document of its own. Turn on
    its Modbus TCP first, in the iSolarCloud app: iHomeManager settings ->
    Forwarding channel settings -> open port 502, 503 or 504. Nothing that
    looks like a serial number is published.
  • The survey also reads a Sungrow Logger1000/3000/4000. If your inverter is
    behind one, answer "a Logger" to the transport question so the Logger
    itself is read too.
  • With a Sungrow SBR battery found on its own unit, the battery's power
    limits now come from its datasheet instead of the BMS's current times
    voltage.
  • The "Cut PV generation" switch is now offered on firmware P022 as well
    as P023.
  • The control test no longer reports "nothing measurable happened" when
    your own battery charge or discharge limit is set low: it tests under the
    limit, or says the limit is why it skipped.
  • The wallbox shows its own serial number on its device page.
  • First control test on an SH20T, thanks to Raik0 (#772), and a second
    reading of an SH10RT-V112, thanks to Korsberg (#785).

Don't miss a new Sungrow-SHx-Inverter-Modbus-Home-Assistant release