Latest firmware release for DIY-Thermocam V1 (Teensy 3.1 / 3.2) and DIY-Thermocam V2 (Teensy 3.6). Adds full USB Protocol v2.0 support so V1 and V2 cameras work directly with DIY-Thermocam Studio (the new desktop app) for live thermal streaming, SD card image browsing, and camera control.
Have a DIY-Thermocam V3 or V4 (Teensy 4.1)? Use DIY-Thermocam 4.0.0 instead. This
2.5.0release is for V1 and V2 hardware only.
Downloads
| Hardware | File |
|---|---|
| DIY-Thermocam V1 (Teensy 3.1 / 3.2, includes USB Mass Storage image) | Firmware_V1.hex
|
| DIY-Thermocam V2 (Teensy 3.6) | Firmware_V2.hex
|
All files bundled (Firmware_V1.hex, Firmware_V2.hex, Changelog.txt)
| DIYThermocam_2.50.zip
|
Flash the .hex file for your board with PJRC Teensy Loader (the in-app updater in Studio 4.0.0 is for Teensy 4.1 V3/V4 boards only). SHA256SUMS.txt lists a checksum for every file.
What's new in 2.50
- DIY-Thermocam Studio compatibility (USB Protocol v2.0): Both V1 (Teensy 3.1/3.2) and V2 (Teensy 3.6) now speak the full binary Protocol v2.0 (
TC2\0) over USB CDC alongside legacy Protocol v1 (0x64), so existing legacy tools continue to work without changes. - Live thermal streaming: Streams raw 16-bit thermal frames (
160×120on Lepton 3.0/3.5,80×60on Lepton 2.0/2.5) with accurate Celsius calibration (cal_offset,cal_slope,spot_temp_c) for both radiometric sensors (Lepton 2.5/3.5) and MLX90614-calibrated sensors (Lepton 2.0/3.0), while keeping the camera LCD live. Also supports320×240rendered frames on V2. - Direct SD card browser in Studio: Browse, preview, open, download, and delete
.DATthermal images and video capture folders straight from DIY-Thermocam Studio over USB (FS_INFO,FS_LIST,FS_STAT,FS_READ,FS_DELETE,FS_ABORT). - Camera settings, diagnostics, and radiometry: Full support for live configuration sync (
GET/SET_CONFIGwith RAM/EEPROM persistence), RTC clock sync, manual FFC trigger with status events, sparse temperature points, remote.DAT/.BMPcapture saving, hardware self-test diagnostics, performance telemetry, async button/touch/battery events, and FLIR Lepton 2.5/3.5 flux-linear emissivity parameters (GET/SET_RAD_PARAMSwith EEPROM persistence). - Includes all fixes from 2.49: Calibration stability fix, EEPROM preset healing, bounded I2C/MLX90614 timeouts, Lepton 2.5/3.5 detection, V1 USB Mass Storage hook fix, VoSPI CRC-16 checking, and fast integer rendering.
Source code is on branch v2.4.x. .DAT captures remain compatible across V1, V2, V3, and V4 cameras and DIY-Thermocam Studio.