github maxritter/diy-thermocam 2.5.0
Firmware Version 2.5.0 (V1 & V2)

one hour ago

Latest firmware release for DIY-Thermocam V1 (Teensy 3.1 / 3.2) and DIY-Thermocam V2 (Teensy 3.6). Adds full USB Protocol v2.0 support so V1 and V2 cameras work directly with DIY-Thermocam Studio (the new desktop app) for live thermal streaming, SD card image browsing, and camera control.

Have a DIY-Thermocam V3 or V4 (Teensy 4.1)? Use DIY-Thermocam 4.0.0 instead. This 2.5.0 release is for V1 and V2 hardware only.

Downloads

Hardware File
DIY-Thermocam V1 (Teensy 3.1 / 3.2, includes USB Mass Storage image) Firmware_V1.hex
DIY-Thermocam V2 (Teensy 3.6) Firmware_V2.hex
All files bundled (Firmware_V1.hex, Firmware_V2.hex, Changelog.txt) DIYThermocam_2.50.zip

Flash the .hex file for your board with PJRC Teensy Loader (the in-app updater in Studio 4.0.0 is for Teensy 4.1 V3/V4 boards only). SHA256SUMS.txt lists a checksum for every file.

What's new in 2.50

  • DIY-Thermocam Studio compatibility (USB Protocol v2.0): Both V1 (Teensy 3.1/3.2) and V2 (Teensy 3.6) now speak the full binary Protocol v2.0 (TC2\0) over USB CDC alongside legacy Protocol v1 (0x64), so existing legacy tools continue to work without changes.
  • Live thermal streaming: Streams raw 16-bit thermal frames (160×120 on Lepton 3.0/3.5, 80×60 on Lepton 2.0/2.5) with accurate Celsius calibration (cal_offset, cal_slope, spot_temp_c) for both radiometric sensors (Lepton 2.5/3.5) and MLX90614-calibrated sensors (Lepton 2.0/3.0), while keeping the camera LCD live. Also supports 320×240 rendered frames on V2.
  • Direct SD card browser in Studio: Browse, preview, open, download, and delete .DAT thermal images and video capture folders straight from DIY-Thermocam Studio over USB (FS_INFO, FS_LIST, FS_STAT, FS_READ, FS_DELETE, FS_ABORT).
  • Camera settings, diagnostics, and radiometry: Full support for live configuration sync (GET/SET_CONFIG with RAM/EEPROM persistence), RTC clock sync, manual FFC trigger with status events, sparse temperature points, remote .DAT/.BMP capture saving, hardware self-test diagnostics, performance telemetry, async button/touch/battery events, and FLIR Lepton 2.5/3.5 flux-linear emissivity parameters (GET/SET_RAD_PARAMS with EEPROM persistence).
  • Includes all fixes from 2.49: Calibration stability fix, EEPROM preset healing, bounded I2C/MLX90614 timeouts, Lepton 2.5/3.5 detection, V1 USB Mass Storage hook fix, VoSPI CRC-16 checking, and fast integer rendering.

Source code is on branch v2.4.x. .DAT captures remain compatible across V1, V2, V3, and V4 cameras and DIY-Thermocam Studio.

Don't miss a new diy-thermocam release

NewReleases is sending notifications on new releases.