Fixed
- MQTT status sweep disconnects (#195): H5110 (a gateway-bridged thermo-hygrometer) is now permanently excluded from the periodic AWS IoT status re-query. Previously it took two dropped sessions per H5110 unit for the reactive quarantine to learn this — with several H5110s on one account, MQTT could take minutes to stabilize after every reconnect. Confirmed root cause via diagnostics from a real multi-H5110 account.
- Orphaned
rate_limit_minute/poll_interval_unsustainableissue-registry entries (pre-dating therate_limitedrepair) are now cleaned up on setup for installs that hit them before the rename.
Added
- H5194 (4-probe) meat thermometer support (#197): the 4-probe sibling of the H5192, on the same transport, registers, and checksum. Probe count is now SKU-aware, so existing H5192 installs are unaffected — no phantom probe 3/4 entities.