Pre-release for testing. Install it only if you want to help test. Stable 1.3.5 follows after testing.
Everything from v1.3.5-beta.2, plus one fix.
What's new
๐งน No second PLUM ecoNET300 device (new in beta.3)
An ecoNET300 module that is still starting can report its device ID as empty. The integration then started without it and registered the controller entities a second time, on a second PLUM ecoNET300 device without an area. Those entities have _2 at the end of their entity ID and never update.
Now the integration waits until the module reports its device ID. When it starts, it removes a second device like this together with its entities. Your real devices, entities and history are not touched.
๐ Ready for Home Assistant 2027.8
On Home Assistant 2026.8 or newer, the log warned that ecoNET300 uses the deprecated via_device device parameter (#264). Home Assistant 2027.8 will stop accepting it.
Mixers, ecoSTER panels, lambda, hot water, buffer, solar, service parameter and advanced parameter devices now link to the PLUM ecoNET300 device the new way, so the warning is gone. On Home Assistant older than 2026.8 nothing changes.
๐ ๏ธ Connection to ecoNET300 device failed no longer gets stuck
After 5 failed updates in a row, ecoNET300 shows this repair in Settings โ System โ Repairs. After a restart a working connection did not remove it. Now it disappears after a restart, and comes back only if the connection still fails.
๐ฆ HACS installs without a log error
HACS logged Could not save ZIP file every time it downloaded ecoNET300. The install still worked, because HACS then downloaded the files one by one. From this version on, HACS installs it in one step without the error.
๐ท๏ธ Alarm active has its name back
The Alarm active binary sensor was shown as Problem. It is now named Alarm active (Alarm aktywny, Alarm aktiv).
Small changes
- The Service parameters and Advanced parameters devices now show the software version and the link to the ecoNET300 web page, like the other devices.
After updating
No reinstall is needed. Device names, entity IDs and history stay the same.
Please test
- No
via_devicewarning in the log on Home Assistant 2026.8 or newer. - No
Not adding entity with invalid device infoorError adding entityin the log. - Sub-devices show Connected via PLUM ecoNET300 on their device page.
- The same number of ecoNET300 entities as before the update.
- After a restart, Repairs shows no Connection to ecoNET300 device failed while the device works.
- Only one PLUM ecoNET300 device. If you had a second one, the log shows
Removing ghost device PLUM ecoNET300once after the update.
Please report the results in #266.
Full changelog: v1.3.4...v1.3.5-beta.3