SomnoTrace v4.0.0
π Series 10 support via SomnoBridge β the headline addition
- Pair, provision and pull therapy data from an AirSense 10 / AirCurve 10
through the SomnoBridge Wi-FiβBLE adapter β the EZShare card stays in the
machine, nothing is swapped. - Clock-drift correction applies to bridge-imported days too: SomnoTrace
anchors its NTP time on the bridge's clock and corrects the AS10's
timestamps, so imported nights line up with your oximeter data. - Bridge status everywhere β LCD indicators for the BLE link and card Wi-Fi,
portal sync progress, and a configure dialog with a card network picker
and insecure-card repair. - Pairing reliability β clean release builds can now bond (SMP and
bond-store fixes that blocked every pairing attempt in earlier betas).
π₯ Imports that don't invent data
- Source fingerprinting β every imported EDF is SHA-256 hashed with its
provenance recorded in the session manifest; re-dropped, growing or
rewritten files are recognised instead of duplicated or guessed. - Late and out-of-order arrivals (EVE/CSL showing up hours after the
waveforms) are matched on evidence, not arrival order; ambiguous sources
stay staged with a stated reason rather than being merged on proximity. - Progressive uploads handled β files trickling in over FTP or manual
copies wait for the group to go quiet before committing; torn files
stage as in-flight, never quarantined. - Persistent import state β unchanged day-groups are skipped, so passes
dropped from ~5 minutes of rebuild churn to sub-second no-ops, and
committed sources are cleaned out of IMPORT/. - Existing sessions are never retroactively modified β fixes apply to new
imports only.
ποΈ Sessions now match your ResMed card
- Mask-off breaks split sessions exactly like the machine does β one EDF
file set per mask-on window, matching the card file-for-file. - Phantom ~120 L/min leak spikes during mask-off are gone from charts and
statistics β leak numbers line up with what OSCAR reports. - Midday sessions record as one continuous session β the forced noon split
is gone (live recording only; imported sessions keep the machine's split). - The final therapy window is no longer truncated by an end-of-session
race (up to ~96 minutes was being lost).
βοΈ Settings that tell the truth
- TiMin, TiMax, Trigger and Cycle now export for AirCurve bilevel profiles
(VAuto, ST, Timed, Spont) β previously written as "no data". - Historical settings require a verified source with matching machine
identity β days that can't prove it show Unknown rather than borrowing
the current machine's values. - AS10 card settings keep the card's own scaling and enum values;
unverified fields stay unknown.
π οΈ Reliability
- Clock-drift fetches now retry β a single BLE timeout can no longer bake
a zero-drift correction into every session of a day (the ~1-hour shift /
"lost session" bug). - HTTP work runs on deferred workers β no more stalled pages or
mid-request resets with multiple tabs open. - PSRAM-backed stacks and buffers for the heavy workers β fewer low-heap
resets. - Upload retry storms parked β a persistently failing unit backs off to
once a day instead of hours of HTTP 429s.
β οΈ Worth knowing
- Without usable STR mask evidence, session pairing still falls back to
the 60-second heuristic β two sessions starting very close together may
be treated as one. - Sessions imported before this release are frozen by design β they are
not repaired, migrated or merged. - Live features (real-time alerts, live graphs, remote start/stop, MQTT
therapy telemetry) remain Series 11 only β Series 10 via SomnoBridge is
file-sync with drift correction.