- increased dumping of logfile by factor 5 / as long as we still have memory left, you can increase logbuflen from 100 to 1000 to increase transfer speed from approx. 16 to 18 kB/s
- adjusted burner activity monitoring based on broadcast messages for Brötje systems
- removed definement PROGNR_5895 because so far, it has only disabled an ENUM definition.
- removed definement PROGNR_6030 because double command ID could be resolved via BROETJE / non-BROETJE definements
- renamed BROETJE_SOB to BROETJE in order to allow for fine-grained distinction between different cases (e.g. 6800ff)
This means you have to activate TWO definements when using a Brötje system now: The general BROETJE as well as BROETJE_SOB or BROETJE_BSW.
Have a look at your serial log for parameters 6800 to see which command IDs fit your system and activate one of both accordingly. - changed 16-Bit addressing of flash memory to 32-Bit to address crashes due to ever growing PROGMEM tables - now we have lots of air to breathe again for new command IDs :)
- removed trailing \0 string from several ENUMs that led to wrong ENUM listings. Please keep in mind not to end ENUMs with a trailing \0 !