[1.4.0b3] - 2026-08-20
Fixed
- Toggling Predictive Charging could make every integration entity unavailable and overflow the dashboard websocket: enabling or disabling the feature no longer reloads the config entry. Predictive diagnostics, mode controls, history capture and the Dynamic Pricing timer now remain registered behind live gates; disabling clears active charging ownership and schedules an immediate normal-control cycle, while enabling Dynamic Pricing rebuilds the remaining-day plan in place.
- Consumption profile sensors used an invalid
measurementstate class for theenergydevice class: the expected home consumption forecast now has no state class because it is recalculated, while the live daily capture usestotal_increasingfor its monotonic accumulation and local-midnight reset. - Repeated warnings while the grid sensor was temporarily unavailable:
unknownandunavailableare now treated as expected transient Home Assistant states and logged only once per episode at debug level. Missing sensors and genuinely malformed values still produce one warning per episode, while automatic control remains safely paused until a numeric reading returns. - Temporary remaining-consumption curve could amplify an already high daily total: live adjustment now reconciles the shaped fallback with the unconsumed daily budget instead of projecting the elapsed excess a second time into the remaining horizon. The existing gradual confidence and 30% bound remain in place, preventing both late-day overcharging and a one-off load spike from erasing plausible future demand.
- Home Consumption could become
unknownafter a transient telemetry mismatch: positive balances are no longer rejected solely because they fell below half of the previous reading, and the display sensor holds its last coherent value during an invalid negative/near-zero balance. Daily energy tracking remains strict and excluded-load control ignores held display values. - Predictive-charging timeline diagnostics could become unknown after a no-charge evaluation: Dynamic Pricing now builds and preserves solar-timeline, solar-profile and projected-depletion diagnostics even when the balance decides that no grid charging is needed, so later balance-only reevaluations cannot erase them from the predictive-charging sensor.
- Top-charge Cell Delta could remain stale when the BMS cut below 3.60 V: a confirmed BMS cutoff in the taper zone now starts the same 60-second settled measurement used at the top-voltage point, including during weekly full charge, so packs that stop at 3.58 V still publish a formal reading.
- Re-saving time slots or excluded devices could reset their runtime controls (#307): the options flow now preserves a time slot's Enabled state and an excluded device's Enabled and Exclusion % values while editing the same record, including when an activity-only device gains a power sensor. Replacing a record still starts from safe defaults instead of inheriting hidden settings. Thanks to @syphernl.