[1.3.0b2] - 2026-08-04
Fixed
- Three-phase manual-mode Repairs warning could appear unnecessarily (#236): the warning is now shown only while manual mode is active or an enabled manual time slot is configured, and it is cleared when neither bypass route is available.
- Incremental PD could oscillate on identical grid-meter publications:
last_reportedis now used for sensor health and cadence, while P/D and predictive control advance only for a new transformed meter value. Unchanged reports no longer trigger a full control cycle, and stale-safety checks remain active. - Sessy power writes could fail with
Server disconnected: the local HTTP driver now avoids stale keep-alive sockets, consumes write responses and retries a control request once after rebuilding its client session.
Changed
- Three-phase protection accepts partial phase layouts: each phase sensor and limit is an optional pair. Leaving both fields empty disables phase protection for that phase, so its batteries continue under normal controller and per-battery limits; incomplete or invalid configured pairs remain fail-safe.