github f18m/viessmann-optolink2mqtt 1.3.2

one hour ago

What's Changed in 1.3.2

Bug Fixes & Reliability

  • Prompt MQTT write handling & startup staggering (#88): Fixed initial register reads to actually stagger by 100 ms (0.1 * (i + 1)) instead of 1 s, and updated the main loop to wait
    directly on the incoming MQTT message queue so queued write requests are processed immediately rather than one per 0.5 s loop quantum.
  • Monotonic clock for scheduling and timeouts (#84): Switched the register polling scheduler and OptolinkVS2Protocol.receive_fullraw() from wall-clock time (time.time) to
    time.monotonic, preventing NTP/clock jumps from stalling polling or triggering read bursts.
  • VS2 protocol request & response validation (#85):
    • receive_telegram() now verifies that incoming response telegrams have a ResponseMessage identifier and match the requested register address (reporting MessageIdError or
      AddressMismatch in error statistics rather than returning stale/mismatched data).
    • read_datapoint_ext(), write_datapoint_ext(), and do_request() now validate addresses (0x0000–0xFFFF) and payload data lengths (0–250 bytes) up front, returning InvalidRequest
      instead of crashing or truncating addresses.
  • MQTT client thread safety & per-instance counters (#83): Moved MqttClient statistics counters from class-level to per-instance attributes and guarded the Home Assistant discovery request
    flag with a lock to avoid losing online notifications between the paho network thread and main thread.

Configuration & Schema Improvements

  • Multiple byte_filter entries per register address (#87): A register address can now appear multiple times in registers_poll_list to extract different bytes of the same register,
    provided every entry for that address specifies a byte_filter.
  • Tighter configuration schema validation (#87):
    • mqtt.broker.port is now optional (defaults to 1883) and validated within 1–65535.
    • mqtt.qos is constrained to 0–2, and register length to 1–250.
    • enum mappings now require integer keys and string labels (map(str(), key=int())), catching misconfigurations like quoted integer keys ("0": "Off") or unquoted YAML booleans (On) at
      startup.

Upgrade Notes

  • Because config schema validation is stricter in 1.3.2, invalid enum definitions (such as quoted numeric keys or unquoted On/Off labels) or out-of-range port, qos, or register
    length values that previously loaded silently will now be rejected on startup.

Don't miss a new viessmann-optolink2mqtt release