Changes between release 11.2.3 and 11.3.0:
- additional units liters/minute, liters/hour
- emonTx4 serial configuration tool (accessible from admin menu)
- automatic firmware update on full update disabled
- list of available firmwares for firmware update tool loaded from remote rather than local copy (removes need to update system to see new firmware versions).
- feed post $arg variable renamed $padding_mode for readability
- feed/list api option to return feed meta data with ?meta=1, provides a performance improvement if meta data is not required.
- fix for null and non numeric error when posting non numeric input data
- fix for zoom visualisation which was not showing partial years
- user guide documentation moved from guide