github dell/dellemc-openmanage-ansible-modules v6.0.0
Release 6.0.0

latest releases: v9.6.0, v9.5.0, v9.4.0...
2 years ago

Release Summary

Added collection metadata for creating execution environments, deprecation of share parameters, and support for configuring iDRAC attributes using idrac_attributes module.

Major Changes

  • Added collection metadata for creating execution environments.
  • Refactored the Markdown (MD) files and content for better readability.
  • The share parameters are deprecated from the following modules - idrac_network, idrac_timezone_ntp, dellemc_configure_idrac_eventing, dellemc_configure_idrac_services, dellemc_idrac_lc_attributes, dellemc_system_lockdown_mode.

Known Issues

  • idrac_user - Issue(192043) The module may error out with the message unable to perform the import or export operation because there are pending attribute changes or a configuration job is in progress. Wait for the job to complete and run the task again.
  • ome_application_alerts_smtp - Issue(212310) - The module does not provide a proper error message if the destination_address is more than 255 characters.
  • ome_application_alerts_syslog - Issue(215374) - The module does not provide a proper error message if the destination_address is more than 255 characters.
  • ome_device_local_access_configuration - Issue(215035) - The module reports Successfully updated the local access setting if an unsupported value is provided for the parameter timeout_limit. However, this value is not actually applied on OpenManage Enterprise Modular.
  • ome_device_local_access_configuration - Issue(217865) - The module does not display a proper error message if an unsupported value is provided for the user_defined and lcd_language parameters.
  • ome_device_network_services - Issue(212681) - The module does not provide a proper error message if unsupported values are provided for the parameters- port_number, community_name, max_sessions, max_auth_retries, and idle_timeout.
  • ome_device_power_settings - Issue(212679) - The module displays the following message if the value provided for the parameter power_cap is not within the supported range of 0 to 32767, Unable to complete the request because PowerCap does not exist or is not applicable for the resource URI.
  • ome_device_quick_deploy - Issue(216352) - The module does not display a proper error message if an unsupported value is provided for the ipv6_prefix_length and vlan_id parameters.
  • ome_smart_fabric_uplink - Issue(186024) - The module does not allow the creation of multiple uplinks of the same name even though it is supported by OpenManage Enterprise Modular. If an uplink is created using the same name as an existing uplink, the existing uplink is modified.

New Modules

  • dellemc.openmanage.idrac_attributes - Configure the iDRAC attributes

Don't miss a new dellemc-openmanage-ansible-modules release