Bugs
- Unable to add/remove archive device extension to/from a device #713
- UI2 : Adding new Attribute Filter and/or Metadata Filter to archive device extension fails #714
- Unable to add/remove Archive AE Extension to/from an application entity #715
- UI2 : Adding new Export Rule to archive device extension or archive AE extension fails #721
- UI2 : Removing attribute values and updating device has no effect #722
- RESTful Service : List configured Storage systems throws NoSuchFileException #723
- Adding a new HL7 Order Scheduled station fails #724
- UI2 : Adding new SPS Status for HL7 Order on archive device extension or archive HL7 application extension fails #726
- SQL Server fails to insert issue records #727
- Copy/Move objects RESTful service fails with status code 409-Conflict #728
- UI : Query MWL service : ScheduledProcedureStepStartDate(=currentDate) being sent in query string even when date fields are kept blank #731
- UI: changes made on the device even if saving doesn't worked. #733
- UI: MWL-s are not showing correct #737
- Query AETs RESTful service : Exception thrown when there is no archive AE extension to an AE of a device #738
- UI: Patient name field has horizontal scrollbar if the text is too long. #741
- UI: Wrong URL for download of uncompressed DICOM instances #745
- UI: if the instance has more than one image, dropdown of the images doesn't work #746
- Wrong PlanarConfiguration after decompression of RLE compressed color images #747
- UI Number of Frames not showing up if there is multiple frame image. #748
- UI: Sorting when you clicks on the arraws not working #753
- STOW-RS: Failed to extract Image Pixel Attributes from JPEG header #754
- dcm4che-tool-jpg2dcm: Failed to extract Image Pixel Attributes from JPEG header #757
- dcm4che-tool-jpg2dcm: OutOfMemoryError on larger input (video) files #758
- UI: on secure archive and secure ui, on login the aetes and exporters are not loaded #759
- UI: Queues-page not working if one of the dates are undefined #760
- UI:Add dropdownlist in the Storage commitements page to the Exporter ID-filter #761
- UI: redirect to login on season timeout #762
- UI: In the device configurator the Fileds with the type number are set to 0 if not defined #765
- UI: Clone of NetworkAE not working on device configurator #766
- Access Control ID not saved correctly in LDAP #768
- UI Configuration: optional boolean attributes cannot be deselected #771
- Archive HL7 Application not associated to Archive AE in default configuration #772
- Query SCP: Return "*" in (0008,0061) Modalities in Studies for Studies with Series without no value for (0008,0060) Modality #775
- Artefacts in decompressed RLE 16bit multi-frame images in all frames except the first #778
Improvements
- findscu: support to specify query params in XML files #671
- UI2- show warning when the user tries to querie the studies without setting any filters #685
- Make Attributes fetched from Leading C-FIND SCP configurable #716
- UI: Show warning when the user tryes to delete an extension #720
- Extend List devices RESTful Service to indicate if device has an archive device extension #725
- Make DicomInputStream.guessTransferSyntax() more robust #729
- Accept HL7 v2 Cancel Patient Transfer/Discharge ADT^A12/A13 message by default #732
- UI: give the user the possibility to see the log that's comming from server on device save failure #734
- Accept HL7 v2 Cancel Admit/Register Patient ADT^A11/A38 message by default #735
- Adding an AE (without Archive AE extension) to archive device causes NPE in query services #739
- Attributes:update(.., Attributes modified): Do not include empty Attributes in passed Attributes modified #743
- UI: Make defaults for attribute values transparent for users #749
- Disable detection of end of frame in EncapsulatedPixelDataImageInputStream for single frame images #752
- UI: Add loader on echo so the user sees that something it's hapaning if timeout infinit #763
- HL7 Service: Suppress Patient Creation by HL7 Messages of specified types #770
- Accept additional HL7 Receiving Application and Facility names by one HL7 Application #773
- QIDO-RS: Do not return private attribute (7777,xx27) Study Access Control ID = "*" #776
New Features
- UI: Import DICOM instances on the local filesystem to the archive using STOW-RS #654
- UI: Import a single JPEG image on the local filesystem to a study in the archive using STOW-RS #655
- UI: Import a single MPEG2 video on the local filesystem to a study in the archive using STOW-RS #656
- UI: Import a single PDF file on the local filesystem to a study in the archive using STOW-RS #657
- RESTful service to compare studies in two archive #730
Tasks
- Provide LDAP Update Scripts in binary distribution packages #711
- UI2 : Enable to create exporter only for devices having archive device extension #712
- Change type of tags in JSON Configuration from integer to string #717
- UI: get allways the device from the server if the user clicks the device in the device list #718
- UI: Implement removing object in device configurator #719
- Replace incorrect env variable ${java.server.temp} by ${java.server.temp.dir} #742
- Archive Docker image: Increase maximal size of POST request to 10GB #755