๐งช 2.11.0 Beta 2
Fenix: Time to ready and Ready at now come from the heater itself (#13). Fenix reports the same remaining heat-up time the MyHarvia app shows ("ready in 38 min"); the integration used to ignore it and estimate the time from how fast the temperature rises, which takes a few minutes to show anything and lags behind a changed target. Thanks to @fubo08 for the contribution.
- Used with the heater's own sensor and target-temperature readiness. If you configured an external reference sensor or a fixed ready temperature, the trend estimate stays in use, because Harvia's figure refers to its own sensor and target.
- After a profile or target change the old estimate is dropped; the new one arrives with the next telemetry frame (about half a minute later).
- The Ready flag and the
harvia_sauna_readyevent are unchanged (still temperature-based). Entity IDs are unchanged. - Xenio is not affected.
Everything from Beta 1 is included โ including the note on automations that use Power (Xenio).