Added
- An Inverter Reactive Power sensor (diagnostic), from register 40024 in EcoFlow's register schema. Confirmed on a PowerOcean Plus, where it follows the built-in meter like Inverter AC Power. On a model that refuses the register, the read is dropped and the sensor stays unknown.
- The register scan reads the registers EcoFlow's register schema lists for the PowerOcean that the integration does not poll yet, such as the battery control mode, the reactive power limits and the house consumption counters, so they can be confirmed on a live inverter first.
- A Run register scan action that reads, without writing anything, the register map, those candidate registers and the address ranges around them from Home Assistant, and puts the report in the diagnostics download, so an untested model can be reported without running the script.
Changed
- At Debug alert verbosity, a failed poll is raised only once polls have kept failing for 3 minutes, as an inverter misses a poll now and then, such as early in the morning. It is still logged at once, and an alert you ignored for it stays ignored.
- The Grid-side Voltage and Current sensors are disabled by the integration while no external EcoFlow Smart Meter has reported, since all six read 0 without one, as on a PowerOcean Plus that uses its built-in meter (#240). They are enabled again once a meter reports, and one you disabled yourself stays disabled. The log says why at each start, and the diagnostics download shows
has_external_meter. - The README has a contents list and is ordered by setup. The sensor tables moved to docs/sensors.md and the battery control details to docs/battery-control.md and the protocol notes to docs/ecoflow-modbus-protocol-implementation.md, and the README links to both from absolute URLs, so they also work where HACS or the Marketplace shows it, and the contents list is left out of the Marketplace.
- The sensor documentation explains which AC readings the inverter measures itself and which come from an external EcoFlow Smart Meter, and that on a PowerOcean Plus the Inverter sensors show its built-in meter at the grid connection.
What's Changed
- Update pymodbus requirement from <4,>=3.16.1 to >=3.16.2,<4 by @dependabot[bot] in #217
- Write entity state when only availability changes by @windmark in #220
- Publish betas from pull requests from forks by @windmark in #224
- Allow checking out a fork's pull request for betas by @windmark in #225
- Report an inverter that stops answering Modbus by @windmark in #223
- Mark control as confirmed working for mode models by @windmark in #226
- Write nothing on reconnect while Modbus Control is off by @windmark in #229
- Distrust readings an inverter stopped updating by @windmark in #230
- Tell the user when the inverter stops updating by @windmark in #231
- Add an alert verbosity setting by @windmark in #233
- Catch stalled readings and add an alert verbosity setting by @windmark in #234
- Remove duplicate line in changelog by @windmark in #235
- Add a grid energy calculation option by @windmark in #228
- Release v2.10.0 by @github-actions[bot] in #236
- Resend requests the connection lost, and use a 10 s timeout by @windmark in #238
- Release v2.10.1 by @github-actions[bot] in #239
- Hide grid-side sensors without an external meter by @windmark in #241
- Restructure the README and move reference docs to docs/ by @windmark in #242
- Add register scan action and register candidates by @windmark in #243
- Move device code into a powerocean package by @windmark in #244
- Split identity and repairs issues out of the coordinator by @windmark in #245
- Use Home Assistant entity descriptions by @windmark in #246
- Group health and tool modules into packages by @windmark in #247
- Bump modbus-connection from 4.12.7 to 4.12.8 by @dependabot[bot] in #249
- Raise a failed poll only after 3 minutes of failures by @windmark in #250
- Release v2.11.0 by @github-actions[bot] in #252
Full Changelog: v2.9.5...v2.11.0