github MaxGramser/homeassistant_espscreen screens-v0.4.82
Tessera 0.4.82 · firmware 0.51.0

one month ago

Tessera 0.4.82 · firmware 0.51.0

No more "999 %" right after a screen starts (#169)

A screen measures how much memory it has for tiles, and it used to take its first measurement the moment Tessera said hello, before its tiles were there. That first minute is the busiest one: Home Assistant sends every state at once and the cards are built, so the screen has some 25 KB less than a minute later. The screen reports the lowest of its last five measurements, so on a board with little memory to spare that one bad minute read as no room at all for about ten minutes, and a restart started it over.

A screen now measures only once its tiles have been on it for a minute. Until then the editor shows Measuring beside the tile count and asks nothing when you add a tile. A screen that really has no memory to spare shows No room in words instead of a share such as 999 %. It is still a warning: you can add the tile, and the screen protects itself if it runs short.

"Update in Tessera first" on a CYD or Hosyond with its original flash layout

Since firmware 0.48.0 the firmware of the CYD, the CYD with an ILI9342 and the Hosyond 4-inch no longer fits the update slot of the flash layout these screens were first installed with. A screen like that turns down an update from ESPHome Device Builder before it writes anything. Tessera moves it to the new layout on the way (since app 0.4.56) and keeps its settings.

The screen's card on the overview and its details in the sidebar now say Update in Tessera first, with an (i) that explains why. The hint goes away once the screen reports the new layout. After that, an update from either place works.

Tested

On the bench with Home Assistant, this app and real screens. With an older app (0.4.77) a CYD and a Waveshare 4.3-inch on this firmware showed no meter for about two minutes after a start and then their room (63 KB and 48 KB), steady after. With this app the meter read "Measuring" six seconds after the Waveshare restarted and 16 % two minutes later. A CYD flashed back to firmware 0.2.104 with ESPHome's own table carried "Update in Tessera first" on its card and in its details, and no other screen did. Earlier the same day an Update in Tessera took such a CYD from 0.2.104 to 0.48.0 over the bridge in eleven minutes, with the new layout. Checked with every Python, C++, editor and WASM preview check. Firmware builds on ESPHome 2026.9.0 for the CYD (90.6 % of its slot), the 4-inch and 10.1-inch Guition, the Waveshare 7-inch and the bridge (34.9 % of the old slot), and on 2026.6.2 for the CYD (92.5 %). "No room" in words is covered by the editor's tests only: no bench screen is that full.

Update

Update the Tessera app first, then press Update on each screen in Tessera.

Don't miss a new homeassistant_espscreen release

NewReleases is sending notifications on new releases.