github Alexwijn/SAT 5.1.0
SafeHarbor

one hour ago

SafeHarbor makes the Smart Autotune Thermostat a lot more careful about what happens when something goes wrong. SAT now hands the boiler back when it loses something it needs, falls back to other temperature sources where it can, and tells you through repair issues what is missing.


New Features

  • Fail-safe: SAT releases the boiler when it unloads, when Home Assistant stops, and when it has missed something it needs for 10 minutes while heating is on. With an OpenTherm Gateway (MQTT or serial) your wall thermostat takes over; ESPHome, EMS-ESP, OTThing and PID ON/OFF have no thermostat to hand back to, so heating is switched off. SAT takes control back by itself once the missing value returns.
  • Backup inside temperature: When the inside temperature sensor is lost for 2 minutes, SAT keeps heating on the wall thermostat, or else the mean of the radiator thermostats, and returns to the sensor as soon as it is back.
  • Repair issues: For a missing inside or outside temperature, rooms that can't be read, a boiler gateway that can't be reached, heating on a backup temperature, and a heating control loop that stopped responding.
  • What blocks heating: The SAT climate entity reports a heating_blocked_by attribute: hvac_off, inputs_missing, window, hot_water or valves_closed.
  • Minimum window closed time: A new option sets how long all windows and doors must be closed before heating resumes.

Improvements

  • Windows: All windows now pause heating as one, and closing them restores exactly the preset from before, also across a restart. A contact sensor that becomes unavailable counts as closed.
  • Rooms: A room whose own temperature sensor goes stale falls back to its thermostat, and the boiler is never limited below what the colder rooms still need.
  • Stale sensors: A sensor that keeps reporting the same value no longer counts as stale.
  • MQTT gateways: SAT waits for a live message, or the online announcement of an OpenTherm Gateway, before trusting a gateway, and follows its offline announcement.
  • Serial gateway: The port is freed and the connection retried when connecting fails.
  • EMS-ESP: The maximum power is only written when it changes and restored on release, and a released boiler keeps receiving the off setpoint.
  • OTThing: Hot water is only reported while the boiler heats it.
  • PWM: Works with boilers that report no return temperature, counts overshoot only while the flame is on, no longer learns from hot water burns, and keeps the hourly cycle limit when PWM switches off.
  • PID controller: The derivative is capped at 10 degrees per hour, and invalid saved values are ignored.
  • Renaming: Renaming the SAT climate entity no longer interrupts heating control.
  • Clean removal: Deleting SAT also removes everything it stored.

Bug Fixes

  • Outside temperatures that are not numbers are skipped.
  • PID and cycle updates and the startup handlers now run in the event loop.
  • A window pause ends when its contact sensors are removed.
  • Error monitoring works with sentry-sdk 3.
  • Fixed the HACS and Home Assistant validation warnings.

Breaking Changes

  • Fail-safe: Without an OpenTherm Gateway, a lost outside temperature, room or boiler connection now switches heating off after 10 minutes instead of carrying on blind. Make sure your sensors are reliable, and keep an eye on the new repair issues.
  • Saving the options: Reloading SAT releases the boiler, which can cost one burner restart.

As always, thank you for your feedback and support!

Full Changelog: 5.0.0...5.1.0